Series 9000

Analyzer

The Baseline Series 9000 is the candidate of choice

whenever accurate, reliable total hydrocarbon analysis is

required.  The Series 9000 analyzer provides unparalleled

flexibility and offers continuous, fully automated gas

analysis over a broad range of concentrations.

The 9000 has a dynamic range from less than 10 ppb on the

low range version and up to 100% as methane on the high

range version. The analyzer has a generous complement of

analog, digital and logic output capabilities.

The analyzer is based on a flame ionization detector (FID)

with FlowGuard electronic control that delivers a small

portion of the sample gas to the detector flame. During the

combustion process, organic or hydrocarbon-based gases

in the sample are ionized then they are detected by the

instrument and reported as a concentration.

The Series 9000 can be configured with internal components

for single or multipoint analysis of non-condensing gas

samples. The automatic calibration feature enhances the

long-term analytical stability of the instrument.  These

features place the instrument well ahead of the competition

in performance, automation, and configurability.

Applications

The Series 9000 is designed to continuously monitor the

total hydrocarbon content of non-condensing gases in a

variety of applications, such as:

Scrubber & oxidizer efficiency

Carbon bed breakthrough detection

Contaminant analysis in pure/ultrapure inert gases

Well logging

Industrial hygiene & safety monitoring

Fenceline (perimeter) monitoring around industrial sites

LEL monitoringD011.1-9000 THA1

Analytical

Detector: Flame ionization detector (FID).

Ranges:

MDQ 0.01ppm, Full-scale 1 to 200ppm (Methane)

MDQ 0.1ppm, Full-scale 1 to 2,000 (Methane)

MDQ 0.3ppm, Full-scale 1  20,000ppm (Methane)

MDQ 0.003%, Full-scale 0.01  100% (Methane)

Repeatability: +/- 1% Full-scale response.

Drift: +/- 1% of full-scale over 24 hours.

Response Time: < 5 seconds to 90% of final reading.

Alarms: Multilevel concentration and fault alarms that

result in audible and visual alarms. Alarms may also be

mapped to relays to control external equipment.

Sampling: Internal single or multipoint modules, for

pre-filtered (<0.1 microns) non-condensing samples,

with or without sample pump.

Calibration: Programmable automatic or manual

calibration.

Support Gas: Hydrogen 35 cc/min, Air 175 cc/min

(typical). Hydrocarbon content must be less than 1

ppm. Fuel blend options available, consult Baseline.

 

D011.1-9000 THAFeatures

Flame ionization detector.

3U case, 19 (48.3cm) rack mountable.

Automatic calibration at user-defined 

intervals.

Internal, multipoint sampling option.

FlowGuard   electronic control of fuel, air

and sample.

Electronic back-pressure regulator with 

sample bypass system ensures fast response.

Discrete, multilevel concentration & fault 

alarms.

Analog output ranges programmable 

from 1ppm  100% full scale.

Programmable relays for concentration 

alarms, events and diagnostics.

Automatic FID ignition, with automatic 

shut-off of sample, fuel and combustion

air.

Remote operation via RS-232 and Ether-

net.

Graphical display and easy to use menu 

system.

D011.1-9000 THA2

#Physical

Series 9000

Total Hydrocarbon Analyzer

Dimensions: 19.00 (48.3cm) W x 14.25 (36.2cm) D x

5.25 (13.3cm) H.

Weight: < 20 lb (9.07kg).

Configuration: Bench-top or rack-mount 19 (48.3cm)

panel.

Connections: 1/4 (6.35mm) tube fitting connectors.

Operating Temperature: 32 - 104 F (0 - 40 C).

Operating Humidity: 0  95% (non-condensing).

Electrical

Power: 90  230 VAC, 50/60Hz, 3A.

Display: 3.4 (8.6cm) x 4.5 (11.4cm) graphical display.

Relay Outputs: 5 programmable form A relays rated

to 3A @ 230V AC (optional additional 9 relay output

board).

Analog Outputs: 1 programmable 0-20mA or 4-20mA

isolated output (optional additional 3 analog output

board).

Digital Outputs: RS-232, Ethernet.

Imputs: Optional digital input board for 3 contact

closure inputs. Supports start analysis, start calibration,

and analyze calibration gas as sample.