Analyzer
The Baseline Series 9000 is the candidate of choice
whenever accurate, reliable total hydrocarbon analysis is
required. The Series 9000 analyzer provides unparalleled
flexibility and offers continuous, fully automated gas
analysis over a broad range of concentrations.
The 9000 has a dynamic range from less than 10 ppb on the
low range version and up to 100% as methane on the high
range version. The analyzer has a generous complement of
analog, digital and logic output capabilities.
The analyzer is based on a flame ionization detector (FID)
with FlowGuard electronic control that delivers a small
portion of the sample gas to the detector flame. During the
combustion process, organic or hydrocarbon-based gases
in the sample are ionized then they are detected by the
instrument and reported as a concentration.
The Series 9000 can be configured with internal components
for single or multipoint analysis of non-condensing gas
samples. The automatic calibration feature enhances the
long-term analytical stability of the instrument. These
features place the instrument well ahead of the competition
in performance, automation, and configurability.
Applications
The Series 9000 is designed to continuously monitor the
total hydrocarbon content of non-condensing gases in a
variety of applications, such as:
Scrubber & oxidizer efficiency
Carbon bed breakthrough detection
Contaminant analysis in pure/ultrapure inert gases
Well logging
Industrial hygiene & safety monitoring
Fenceline (perimeter) monitoring around industrial sites
LEL monitoring
Analytical
Detector: Flame ionization detector (FID).
Ranges:
MDQ 0.01ppm, Full-scale 1 to 200ppm (Methane)
MDQ 0.1ppm, Full-scale 1 to 2,000 (Methane)
MDQ 0.3ppm, Full-scale 1 20,000ppm (Methane)
MDQ 0.003%, Full-scale 0.01 100% (Methane)
Repeatability: +/- 1% Full-scale response.
Drift: +/- 1% of full-scale over 24 hours.
Response Time: < 5 seconds to 90% of final reading.
Alarms: Multilevel concentration and fault alarms that
result in audible and visual alarms. Alarms may also be
mapped to relays to control external equipment.
Sampling: Internal single or multipoint modules, for
pre-filtered (<0.1 microns) non-condensing samples,
with or without sample pump.
Calibration: Programmable automatic or manual
calibration.
Support Gas: Hydrogen 35 cc/min, Air 175 cc/min
(typical). Hydrocarbon content must be less than 1
ppm. Fuel blend options available, consult Baseline.
|
Features
Flame ionization detector.
3U case, 19 (48.3cm) rack mountable.
Automatic calibration at user-defined
intervals.
Internal, multipoint sampling option.
FlowGuard electronic control of fuel, air
and sample.
Electronic back-pressure regulator with
sample bypass system ensures fast response.
Discrete, multilevel concentration & fault
alarms.
Analog output ranges programmable
from 1ppm 100% full scale.
Programmable relays for concentration
alarms, events and diagnostics.
Automatic FID ignition, with automatic
shut-off of sample, fuel and combustion
air.
Remote operation via RS-232 and Ether-
net.
Graphical display and easy to use menu
system.

#Physical
Series 9000
Total Hydrocarbon Analyzer
Dimensions: 19.00 (48.3cm) W x 14.25 (36.2cm) D x
5.25 (13.3cm) H.
Weight: < 20 lb (9.07kg).
Configuration: Bench-top or rack-mount 19 (48.3cm)
panel.
Connections: 1/4 (6.35mm) tube fitting connectors.
Operating Temperature: 32 - 104 F (0 - 40 C).
Operating Humidity: 0 95% (non-condensing).
Electrical
Power: 90 230 VAC, 50/60Hz, 3A.
Display: 3.4 (8.6cm) x 4.5 (11.4cm) graphical display.
Relay Outputs: 5 programmable form A relays rated
to 3A @ 230V AC (optional additional 9 relay output
board).
Analog Outputs: 1 programmable 0-20mA or 4-20mA
isolated output (optional additional 3 analog output
board).
Digital Outputs: RS-232, Ethernet.
Imputs: Optional digital input board for 3 contact
closure inputs. Supports start analysis, start calibration,
and analyze calibration gas as sample.
|